Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 553 PID: PID 157 SPN: 157 FMI: 16 Injector Metering Rail 1 Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level

Circuit Description
The engine control module (ECM) monitors engine operating conditions, including the reading of fuel rail pressure, and changes the flow command to either increase (OPEN the fuel pump actuator) or decrease (CLOSE the fuel pump actuator) the fuel supply to the high-pressure pump.

Component Location
The high-pressure fuel pump is mounted to the gear housing. The fuel pump actuator is mounted on the fuel pump. The fuel pressure sensor is mounted in the high pressure fuel rail. The fuel pressure relief valve is mounted on the high pressure fuel rail.

Conditions for Running the Diagnostics
This diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault Codes
The Engine Control Module (ECM) detected the fuel rail pressure reading was greater than the commanded fuel rail pressure.

Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
Exhaust Gas Recirculation (EGR) valve operation will be disabled.
Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.
Conditions for Clearing the Fault Code
To validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.
To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.
The fault code status displayed by INSITEâ„¢ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
The Reset All Faults command in INSITEâ„¢ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk
A fuel pump actuator with excessive leakage or a damaged inboard o-ring will result in high fuel rail pressures at idle or light load.

Possible Cause:
1) Fuel rail pressure sensor failure
2) Fuel Pump Actuator failure
3) ECM calibration