Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.
Possible causes:
1)Signal shorted to ground in the harness
2)Signal shorted to return or ground in the sensor.
Possible repairs:
1)Replace the OEM temperature sensor.
2)Repair or replace the OEM harness.
3)Replace the ECM.