Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.
This fault code is triggered when the EGR valve is closed during an active regeneration of the aftertreatment diesel particulate filter. No failure of the aftertreatment system has occurred. Closing the EGR valve increases the exhaust temperature and speeds up the rate of regeneration of the aftertreatment diesel particulate filter. No troubleshooting of the aftertreatment system is necessary. This fault code is for information only.
No repair is necessary.