Cummins ISX15 CM2250 (2010-12) Fault Code: 3582 (MR) PID: SPN: 4364 FMI: 18 Aftertreatment SCR catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level

Circuit Description
The engine control module (ECM) monitors the mono-nitrogen oxides (NOx) concentration in the engine’s exhaust gases using an aftertreatment intake NOx sensor and an aftertreatment outlet NOx sensor. By comparing these two values, the ECM is able to determine the conversion efficiency of the selective catalystic reduction (SCR) catalyst and dosing system.

Component Location
The SCR catalyst is located in the vehicle’s exhaust system, after the diesel particulate filter and decomposition tube.

Conditions for Running the Diagnostics
This diagnostic has to meet specific engine and aftertreatment conditions to run and complete. NOx sensor data is gathered over varying engine speeds and loads. When enough data has been gathered, the diagnostic will run, make a pass/fail decision, and begin to gather data again.

Conditions for Setting the Fault Codes
The ECM detects that the NOx conversion across the SCR catalyst is lower than expected.

Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE lamp and/or the malfunction indicator lamp (MIL) immediately when the diagnostic runs and fails.
Conditions for Clearing the Fault Code
After completing a stationary regeneration (as instructed in this fault code troubleshooting tree) and no additional faults become active, the repair has been validated.
NOTE: The fault code will still be active.

It is necessary to use the “Reset All Faults” command in INSITE? electronic service tool to clear this fault code and turn off the amber CHECK ENGINE lamp and/or MIL.

Shop Talk
Troubleshoot all other active NOx sensor and SCR dosing system related fault codes before this fault.

Possible causes of this fault code include:

Malfunctioning diesel exhaust fluid (DEF) dosing system
Exhaust system leaks
Malfunctioning SCR catalyst
Degraded, diluted, or incorrect DEF
Diesel exhaust fluid deposits in decomposition tube.
This fault code can be set as a result of multiple failure modes. All steps of the troubleshooting tree must be completed.

Possible Cause:
1) Aftertreatment NOx Sensor failure
2) Aftertreatment DEF dosing unit filter failure
3) Aftertreatment DEF dosing valve failure
4) ECM calibration

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Cummins ISX15 CM2250 (2010-12) Fault Code: 3582 (MR) PID: SPN: 4364 FMI: 18 Aftertreatment SCR catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level”

Your email address will not be published. Required fields are marked *

1 2 3 4 5
1 2 3 4 5
1 2 3 4 5