Cummins ISX15 CM2250 (2010-12) Fault Code: 2272 PID: 27 SPN: 27 FMI: 4 EGR Valve Position Circuit- Voltage Below Normal or Shorted to Low Source

Circuit Description
The exhaust gas recirculation (EGR) valve is controlled by a brushless motor located on top of the EGR valve. The EGR valve motor uses three different motor legs to move the valve through its range of motion. The ECM uses the EGR motor A, B, and C wires to command the EGR valve to the appropriate position in order to meet EGR flow targets.

The EGR valve motor contains three position sensors that detect the location of the EGR valve. These sensors report the position of the valve back to the ECM over the EGR valve position A, B, and C wires.

Component Location
The EGR valve position sensor is internal to the EGR valve assembly and can not be serviced separately.

Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Codes
The ECM detects that the EGR valve position sensor signal voltage is less than a calibrated value.

Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE light and/or the malfunction indicator lamp (MIL) immediately when the diagnostic runs and fails.
The EGR valve operation will be disabled.
Conditions for Clearing the Fault Code
To validate the repair, perform a key cycle, and leave the key in the ON position for 1 minute. The EGR valve will perform an auto-zero immediately after keyon.
The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ECM will turn off the amber CHECK ENGINE lamp after the diagnostic runs and passes.
For On-Board Diaganostic (OBD) engines, the ECM will turn off the MIL after three consecutive trips where the diagnostic runs and passes.
The ?Reset All Faults? command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk
The EGR valve position sensor wiring is shorted to ground, open circuit, or shorted to power supply.

Loss of the EGR valve position sensor supply voltage or the ground circuit.

Possible Cause:
1) Engine Harness
2) ECM failure