Cummins ISX CM870 (2003-06) Fault Code: 196 (3 wire) PID: P111 SPN: 111 FMI: 4/4 Coolant Level Sensor 1 Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at the engine coolant level circuit.

Possible causes:

1)Open signal circuit in the engine harness, connectors, or sensor
2)Signal circuit shorted to ground in the engine harness, connector, or sensor
3)Damaged sensor.

Possible repairs:

1)Replace the engine coolant level sensor.
2)Repair or replace the OEM harness.
3)Replace the ECM.

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Cummins ISX CM870 (2003-06) Fault Code: 196 (3 wire) PID: P111 SPN: 111 FMI: 4/4 Coolant Level Sensor 1 Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at the engine coolant level circuit.”

Your email address will not be published. Required fields are marked *

1 2 3 4 5
1 2 3 4 5
1 2 3 4 5