Cummins ISX CM870 (2003-06) Fault Code: 196 (2 wire) PID: P111 SPN: 111 FMI: 4/4 Coolant Level Sensor 1 Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at the engine coolant level circuit.

Possible causes:

1)Signal circuit shorted to ground in the harness, sensor or connectors.

Possible repairs:

1)Replace the engine coolant level sensor.
2)Repair or replace the OEM harness.
3)Replace the ECM.