Cummins ISM CM875 (2003-06) Fault Code: 435 PID: P100 SPN: 100 FMI: 2/2 Engine Oil Pressure Sensor Circuit – data incorrect. An error in the engine oil pressure sensor signal was detected by the ECM.

At key-on, before the engine is started, the sensor readings for barometric pressure, exhaust gas pressure, and intake manifold pressure are compared with engine oil pressure. This fault code occurs if the engine oil pressure sensor reading is different from any two of the other three. This check is only done once after the keyswitch is turned on and before the engine is started. The engine oil temperature must also be at least 7?C [45?F] for this check to run.

Shop exhaust fans can cause this fault code to come active. Turn exhaust fans off when troubleshooting this fault code.

Possible repair:

1)Repair or replace the engine oil pressure switch.