Cummins ISC CM2150 (2007-09) Fault Code: 2347 PID: SPN: 2790 FMI: 0 Turbocharger Compressor Outlet Temperature (Calculated) – Data Valid but Above Normal Operational Range – Least Severe Level. High turbocharger compressor outlet air temperature has been calculated by the electronic control module (ECM).

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.

Possible caused:

1)Air intake leaks allowing hot under-hood air to enter the intake system
2)Faulty intake manifold pressure readings
3)High turbocharger speed readings
4)Faulty barometric pressure readings
5)Stuck variable geometry turbocharger.

Note: Unless the failure is a failed barometric pressure sensor or intake manifold pressure sensor, this fault code will most likely not be active with no load in the shop. The engine will most likely need to be loaded to trip this fault code, and to determine if the failure has been found and fixed.

Possible repairs:

1)Replace the barometric pressure sensor.
2)Replace the intake manifold pressure sensor.

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Cummins ISC CM2150 (2007-09) Fault Code: 2347 PID: SPN: 2790 FMI: 0 Turbocharger Compressor Outlet Temperature (Calculated) – Data Valid but Above Normal Operational Range – Least Severe Level. High turbocharger compressor outlet air temperature has been calculated by the electronic control module (ECM).”