Cummins ISC CM2150 (2007-09) Fault Code: 1675 PID: SPN: 3249 FMI: 3 Aftertreatment Exhaust Gas Temperature 2 Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage detected at the aftertreatment diesel particulate filter inlet temperature sensor circuit.

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.

The catalyst inlet temperature sensor shares return wires in the OEM harness with other sensors. A shorted return can cause multiple fault codes to be active.

Possible causes:

1)Open return circuit in the harness, connectors, or sensor
2)Open signal circuit or shorted to a voltage source.

Possible repairs:

1)Replace the aftertreatment diesel particulate filter inlet temperature sensor.
2)The removal and installation of the connector may correct the fault.
3)Replace the OEM harness, aftertreatment harness, and all interconnects.
4)Replace the ECM.

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Cummins ISC CM2150 (2007-09) Fault Code: 1675 PID: SPN: 3249 FMI: 3 Aftertreatment Exhaust Gas Temperature 2 Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage detected at the aftertreatment diesel particulate filter inlet temperature sensor circuit.”

Your email address will not be published. Required fields are marked *

1 2 3 4 5
1 2 3 4 5
1 2 3 4 5