Cummins ISB6.7 CM2350 (2013-17) Fault Code: 2349 PID: SID 146 SPN: 2791 FMI: 5 EGR Valve Control Circuit- Current Below Normal or Open Circuit
Circuit Description
The exhaust gas recirculation (EGR) valve is controlled by a brushless motor located on top of the EGR valve. The EGR valve motor uses three different motor legs to move the valve through its range of motion. The ECM uses the EGR motor A, B, and C wires to command the EGR valve to the appropriate position in order to meet EGR flow targets.The EGR valve motor contains three position sensors that detect the location of the EGR valve. These sensors report the position of the valve back to the ECM over the EGR valve position A, B, and C wires.
The EGR valve motor contains three position sensors that detect the location of the EGR valve. These sensors report the position of the valve back to the ECM over the EGR valve position A, B, and C wires.
Component Location
The EGR Valve and EGR Differential Pressure Sensor location varies depending on engine model.
Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.
Conditions for Setting the Fault Codes
The Engine Control Module (ECM) detected an open circuit in the engine wiring harness or EGR valve motor coil.
Action Taken When the Fault Code is Active
1)The ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
2)Exhaust Gas Recirculation (EGR) valve operation will be disabled.
3)Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.
Conditions for Clearing the Fault Code
1)To validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.
2)To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.
3)The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
4)The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
5)For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
6)The Reset All Faults command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Possible causes:
1) EGR motor circuit open circuit
2) Open circuit in the wiring harness
3) Malfunctioning ECM.
Reviews
Clear filtersThere are no reviews yet.