Cummins ISB6.7 CM2150 (2007-09) Fault Code: 245 PID: SID 033 SPN: 647 FMI: 4 Fan Control Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at the fan control circuit when commanded ON.

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.

The fan control logic can be adjusted with INSITE™ electronic service tool. There are two choices: 12 or 24 volts ON, or 0 volts ON. For proper fan operation, the fan control logic setup with INSITE™ electronic service tool must match the hardware configuration on the vehicle.

This fault code is logged when the ECM commands 12 or 24 VDC to the fan control solenoid, but the voltage on the fan control signal circuit is less than 12 or 24 VDC. The low voltage on the signal circuit usually indicates a short circuit to ground in the harness or solenoid.

If Fault Code 245 is still active after completing the following troubleshooting steps, consult the OEM troubleshooting and repair manual for procedures to check the fan control circuit for a short circuit to ground.

Possible repairs:

1)Replace the fan control solenoid.
2)Repair or replace the OEM harness.
3)Replace the ECM.

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Cummins ISB6.7 CM2150 (2007-09) Fault Code: 245 PID: SID 033 SPN: 647 FMI: 4 Fan Control Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at the fan control circuit when commanded ON.”

Your email address will not be published. Required fields are marked *

1 2 3 4 5
1 2 3 4 5
1 2 3 4 5