Cummins ISB6.7 CM2150 (2007-09) Fault Code: 2376 PID: 412 SPN: 412 FMI: 4 Exhaust Gas Recirculation Temperature Sensor Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at EGR temperature circuit.

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.

The EGR temperature sensor shares return wires in the engine harness with other sensors. An open return can cause multiple fault codes to be active.

Possible causes:

1)A signal shorted to ground in the harness

Possible repairs:

1)Replace the EGR temperature sensor.
2)Replace the ECM.
3)Repair or replace the engine harness.