Detroit DD16 GHG14 (2014-16) Fault Code: SPN 706 FMI 3 (CPC) Digital Output 3 10 Circuit Failed High

DESCRIPTION:
CPC Output 3 10 short to voltage.

MONITORED PARAMETER:
CPC Output 3/10.

TYPICAL ENABLING CONDITIONS:
Always enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
Two seconds

DASH LAMPS:
CEL

ENGINE REACTION:
None

VERIFICATION:
Engine on with output activation.

POSSIBLE CAUSES:
Pin 10 of the CPC4 #3 connector has a wiring problem.