Detroit DD15 GHG14 (2014-16) Fault Code: SPN 708 FMI 3 (CPC) Digital Output 3 12 Circuit Failed High

DESCRIPTION:
CPC output 3 12 short to voltage.

MONITORED PARAMETER:
CPC output 3/12.

TYPICAL ENABLING CONDITIONS:
Always enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
Two seconds

DASH LAMPS:
CEL

ENGINE REACTION:
None

VERIFICATION:
Engine on with output activation.

NOTE: Pin 12 of the CPC4 #3 connector has a wiring problem.

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Detroit DD15 GHG14 (2014-16) Fault Code: SPN 708 FMI 3 (CPC) Digital Output 3 12 Circuit Failed High”

Your email address will not be published. Required fields are marked *

1 2 3 4 5
1 2 3 4 5
1 2 3 4 5